Electricity: Understanding How It Works: Grounding


Circuit breakers, fuses, ground-fault circuit interrupters (GFCIs), arc-fault circuit interrupters (AFCIs), transient-voltage surge suppressors (TVSSs) and other protective devices are a home's first line of defense against electrical accidents. Equally important is the grounding system, which normally doesn't carry current but must always be on guard to provide a safe path for abnormal current flow and to ensure protective devices' quick operation.

The basics. The principles of grounding are simple but often misunderstood, even by experienced electricians. The term grounded is defined in the code as meaning “connected to earth or to some conducting body that serves in place of earth,” such as a grounded metal electrical box. The earth as a whole is a conductor and is assumed to have a voltage potential of zero, but it's made of different types of soil that resist cur rent flow and don't conduct electricity very well.

Electricity always seeks the path of least resistance to return to its source, usually the utility's transformer. Instead of the earth itself, grounding wires are used to ground all metal objects and provide an effective low-resistance, highly conductive path for abnormal current. Grounding all metal objects also ensures they are at the same safe zero-voltage potential as the earth. If a hot wire comes in contact with a grounded metal object, the low-resistance grounding wires carry the maximum current necessary to quickly trip the circuit breaker or protective device. The grounding wires try to keep the metal object close to the earth's zero-voltage potential to reduce the shock hazard.

Electrical systems and equipment are connected to ground rods, underground metal water pipes and other electrodes to limit and stabilize the voltage to ground during normal operation and to prevent excessive voltages from lightning strikes, power surges or accidental contact with high-voltage utility lines.


Are you looking for home electrical items -- such as switches and fuse boxes -- or parts and accessories for ones you already have? Try our dedicated electrical supply pages here:


Brand Name Manufacturers
Service equipment is usually grounded to the underground metal water pipe within 5 ft. (1.5 m) of the point of entrance into the building. Because of the growing use of plastic water pipe, the code requires one or more supplemental electrodes, such as a ground rod. Copper-coated ground rods must be at least 8 ft. (2.5 m) in length, 1/2 in. (13 mm) in diameter and driven flush with or below the earth. Interior metal piping systems must be grounded by installing a wire called a bonding jumper around water meters and filters. Use only approved clamps for ground rod and metal pipe connections.

Service equipment is usually grounded to the underground metal water pipe within 5 ft. (1.5 m) of the point of entrance into the building. Because of the growing use of plastic water pipe, the code requires one or more supplemental electrodes, such as a ground rod. Copper-coated ground rods must be at least 8 ft. (2.5 m) in length, 1/2 in. (13 mm) in diameter and driven flush with or below the earth. Interior metal piping systems must be grounded by installing a wire called a bonding jumper around water meters and filters. Use only approved clamps for ground rod and metal pipe connections.


GFCI. Turn off power to the receptacle outlet at the service panel. Check to make sure the power is off. Care fully unscrew the outlet and pull it out of the box. (You may need to install a larger box to safely contain the wires and new GFCI).

Making Older Receptacles Safer

You can increase the safety of your old two-prong outlets in two ways. Installing GFCI outlets will protect against a deadly shock even if the outlet isn't connected to a grounding wire. If you have grounded metal conduit and boxes, new three-prong outlets can be installed.

GFCI. Turn off power to the receptacle outlet at the service panel. Check to make sure the power is off. Care fully unscrew the outlet and pull it out of the box. (You may need to install a larger box to safely contain the wires and new GFCI). Disconnect wires from the old outlet and splice them to 6-in. (15-cm) pigtails of white or black wire. Connect the new wires to the GFCI terminals marked “Line,” attaching the black wire to the brass screw and the white wire to the silver screw. Fold wires neatly into the box, fasten the GFCI and plate, and attach the stickers that say “No Equipment Ground.”

 

(continue ...)

Recommended Reading

The Complete Guide to Home Wiring

Book Description:

One of the most daunting endeavors for any would-be do-it-yourselfer is dealing with the electrical--namely, electrical repairs, improvements, and wiring and rewiring projects. The reason for this is simple: mistakes can cause fires, major disasters and expense, and even death. But anyone can learn about safe and correct wiring in order to complete repairs or add new wiring to an aging and inadequate system. This is the book to show you how, from the basics of how electricity works and simple repairs and projects, all the way to complicated rewiring you might otherwise assume must be done by a professional. Included are the most up-to-date electrical code requirements; guides to evaluating, planning, and installing new electrical circuits; repair advice on switches, receptacles, and fixtures; and a detailed and well-illustrated lighting design section. A total of 288 pages of hundreds of illustrations and photographs and a comprehensive reference index make this an ideal book for the beginner, and an up-to-date refresher course for the professional.

Topics include:

see circuit map, black circuit wire, subpanel feeder breaker, white circuit wire, circuit breaker subpanel, neutral wire connection, wire connection box, black wire lead, white wire lead, demarcation jack, black feed wire, first electrical box, neon circuit tester, bare copper grounding wire, main circuit breaker panel, common screw terminal, setscrew terminals, slimline breakers, touching one probe, network wiring system, hot circuit wires, main service panel, silver screw terminal, grounding pigtail, grounding screw terminal

Reviews:

...when my cooktop was malfunctioning, I was able to trace the problem and fix it. I could read the wiring diagram attached to the cooktop and figure out where the problem was. The book doesn't show you how. But once you know a few things, you can build on that knowledge.

A part of my house lost power. I tracked the problem down to a covered box that had wiring held together with electrical tape and some of the wires appeared to have oxidized because of the bad connection. I cleaned up and joined the right wires with connectors, and fixed the problem.

My next step is to add a few ceiling fans in my home. Then maybe a wireless switch so I won't have to walk to my door in pitch darkness. Wire my yard for low-voltage lighting. I feel very inspired, because I feel very informed. And the book definitely paid for itself.

Recommended Products



More | go to top of page

Want to learn more about home electricity? Visit our home electricity library.

If you need home electricity supplies, browse through the products on these pages:


Three-prong: Components: Ground clip, Metal conduit, Metal box, Existing hot wire and neutral wire, New ground pigtail, Grounding-type receptacle.Three-prong grounding-type outlets can be installed only as replacements where a grounding means is available, such as metal conduit, metal armored cable, flexible- metal conduit and their metal boxes. One can also install a ground from elsewhere on the grounding electrode system by using a wire of the same gauge as the branch-circuit conductors. Turn off power to the receptacle outlet at the service panel. Check to make sure the power is off. Carefully unscrew the outlet and pull it out of the box. Connect the black wire to the brass screw and the white wire to the silver screw. Install a bare or green-insulated bonding jumper from the green ground screw on the outlet to the metal box using a green ground clip or green ground screw threaded into the back of the box. Fold wires neatly into box and install the outlet and plate.

Three-prong. Three-prong grounding-type outlets can be installed only as replacements where a grounding means is available, such as metal conduit, metal armored cable, flexible- metal conduit and their metal boxes. One can also install a ground from elsewhere on the grounding electrode system by using a wire of the same gauge as the branch-circuit conductors. Turn off power to the receptacle outlet at the service panel. Check to make sure the power is off. Carefully unscrew the outlet and pull it out of the box. Connect the black wire to the brass screw and the white wire to the silver screw. Install a bare or green-insulated bonding jumper from the green ground screw on the outlet to the metal box using a green ground clip or green ground screw threaded into the back of the box. Fold wires neatly into box and install the outlet and plate.

 

Last modified: Friday, 2020-05-01 11:05 PST